Related Experiment Video
Updated: Oct 28, 2025

Measuring Relative Insulin Secretion using a Co-Secreted Luciferase Surrogate
Published on: June 25, 2019
Ultrarapid Lispro Demonstrates Similar Time in Target Range to Lispro with a Hybrid Closed-Loop System
Bruce Bode1, Anders Carlson2, Rong Liu3
1Atlanta Diabetes Associates, Atlanta, Georgia, USA.
Abstract:
Automated insulin delivery systems are associated with improved glycemic outcomes for patients with diabetes. Ultrarapid lispro (URLi), which has an accelerated pharmacokinetic profile and shows superior postprandial glucose control compared to lispro (Humalog®), is a potential candidate for use in these systems. In this double-blind, crossover trial over two 4-week treatment periods, we evaluated URLi in a hybrid closed-loop system using the Medtronic MiniMed™ 670G system (670G). After a 2-week lead-in on lispro, 42 adults with type 1 diabetes were randomized to 1 of 2 treatment sequences of URLi and lispro delivered via the 670G. Primary endpoint was the percentage of time with glucose values within target range 3.9-10.0 mmol/L (70-180 mg/dL; %TIR). Both treatments achieved %TIR over the 24-h period that was above the 70% minimum recommended by the International Consensus Guidance: URLi, 77.0%; lispro, 77.8%; P = 0.339. %Time <3.0 mmol/L (54 mg/dL) was similar between treatments (URLi, 0.3%; lispro, 0.4%; P = 0.548) and %time <3.9 mmol/L (70 mg/dL) was lower with URLi (1.5%) versus lispro (2.2%); P = 0.009, while %time >10.0 mmol/L (180 mg/dL) was higher with URLi (21.5% [309.4 min] vs. 19.9% [287.2 min]; P = 0.088). Mean sensor glucose was significantly higher with URLi versus lispro with least squares mean difference of 0.17 mmol/L or 3.0 mg/dL (P = 0.011) between treatments. Insulin dose, %time in Auto Mode per week, and pump settings were similar between treatments. No serious adverse events (AEs) (including severe hypoglycemia) or discontinuations occurred, and the incidence of treatment-emergent AEs was similar between treatments. Although the overall incidence and rate of unplanned infusion set changes were similar between treatments, a significantly higher rate of unplanned infusion set changes due to infusion site reactions was seen during URLi treatment compared with lispro: 0.12 versus 0.00 events/30 days (P = 0.063). URLi demonstrated good glycemic control that was comparable to lispro and showed a similar safety profile to lispro with the 670G hybrid closed-loop system. Trial registration: ClinicalTrials.gov, NCT03760640.
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Oral Hypoglycemic Agents: Glinides
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...

