Related Experiment Video
Updated: Oct 28, 2025

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation
Published on: July 15, 2015
Perfusion of a Kidney Graft from a Donor After Cardiac Death Based on Immediately Started Machine Perfusion: An
Václav Opatrný1, Vladislav Třeška1, Jan Zeithaml2
1Faculty of Medicine in Plzen, Department of Surgery, Charles University, University Hospital in Plzen, Plzen, Czech Republic; Faculty of Medicine in Plzen, Transplantcentrum, Charles University, University Hospital in Plzen, Plzen, Czech Republic.
Background:
Donation after circulatory death donors are becoming a common source of organs for transplant. Despite good long-term outcomes of grafts from donation after circulatory death, this group is affected by a higher occurrence of delayed graft function and primary nonfunction. Our hypothesis is based on the assumption that washing the kidney grafts in the donor's body using a simple mechanical perfusion pump will result in faster and better perfusion of the parenchyma and more efficient cooling compared with hydrostatic perfusion alone.
Methods:
A total of 7 experimental animals (pigs) were used. The animals were divided into 2 groups: group A (n = 3) and group B (n = 4). After a 30-minute ischemic period for the selected kidney (clamped renal vessels), intra-arterial perfusion was performed. In group A perfusion was performed using hydrostatic pressure; in group B mechanical controlled perfusion was performed. After perfusion, declamping of the renal vessels caused restoration of flow. For graft quality evaluation, biopsy specimens were harvested, and the cooling speed was observed. Laboratory markers or renal failure were determined.
Results:
We found no significant differences between temperature drop and total diuresis between groups A and B. A significant difference was found between the groups in both flow parameters (flow maximum and mean flow) (P = .007, respectively P = .019). No laboratory parameters were found to be statistically significantly different. Histopathological analysis strongly supports the hypothesis of better flushing of kidney grafts using mechanical perfusion.
Conclusions:
Based on our results, better kidney graft quality can be expected after immediately started mechanical perfusion in situ.