Related Experiment Video
Updated: Oct 28, 2025

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Quercetin-rGO based mercury-free electrode for the determination of toxic Cd (II) and Pb (II) ions using DPASV
K Krishna Kumar1, M Devendiran2, P Senthil Kumar3
1Department of Analytical Chemistry, School of Chemical Science, University of Madras, Guindy Campus, Chennai, Tamil Nadu, 600025, India; Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, 603110, India.
Abstract:
Metal ion pollution poses serious threat to environment. Analysis of Cd (II) and Pb (II) ions using chemically modified mercury free electrode is a feasible routine analytical tool. Developing an electrode surface modified with conductive 2D carbon and metal complexing ligand created a synergetic effect towards sensitive and selective electrochemical determination of metal ions. The present study focused on green chemistry approach towards synthesis of reduced graphene oxide using a natural flavonoid (Quercetin) that acts as a reducing, functionalizing agent and also as metal complexing agent. This quercetin reduced graphene oxide (Q-rGO) was surface modified over paraffin wax impregnated graphite electrode. The resulting Q-rGO electrode was used as a mercury-free electrode for simultaneous analysis of Pb (II) and Cd (II) ions. Physico-chemical parameters of the synthesized Q-rGO and modified electrodes were characterized using X-ray diffraction, UV-Vis, FT-IR, and Raman spectrometer. The morphology of the material and surface topography of the modified electrode was observed using HR-TEM and FESEM, respectively. Cyclic voltammetry (CV) and AC impedance (EIS) were adopted for electrochemical characterization and Differential pulse anodic stripping voltammetry (DPASV) was chosen for simultaneous sensing of metal ions using Q-rGO electrode. Analytical parameters such as effect of electrolyte, effect of pH, preconcentration time and deposition potential were optimized. The experimental results suggested that the Q-rGO electrode is capable of sensing Pb (II) and Cd (II) ions individually and simultaneously. Inference from the calibration plot showed that the Q-rGO electrode was capable of sensing the concentration range of Cd (II) ion form 0.19 to 2.5 μgL-1 with LOD-0.05 μgL-1 and Pb (II) ions from 0.19 to 3.1 μgL-1 with LOD 0.06 μgL-1.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
12:59A Study of the Complexation of MercuryII with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016