Related Experiment Video
Updated: Oct 28, 2025

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
Published on: August 4, 2020
[Development and clinical application of custom-made temporomandibular joint-skull base combined prosthesis]
1Department of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine & College of Stomatology, Shanghai Jiao Tong University & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Shanghai Key Laboratory of Stomatology, Shanghai 200011, China.
Abstract:
Objective: To introduce the design, manufacture and clinical application of the custom-made temporomandibular joint (TMJ)-skull base combined prosthesis and evaluate its safety, effectiveness and accuracy. Methods: The patients diagnosed with the TMJ-skull base lesion in Department of Oral Surgery, Shanghai Ninth People's Hospital from October 2016 to November 2020 were recruited in this study. The maxillofacial CT data for all the patients were obtained and transformed into the Mimics 18.0 software preoperatively. The custom-made TMJ-skull base combined prosthesis, included four components, was designed based on the anatomy, stress distribution and movement of the TMJ and skull base, and fabricated by three-dimensional printing and 5-axis milling technologies. The TMJ-skull base lesion was excised completely with the help of digital templates from modified preauricular and/or post and submandibular incisions. The combined prosthesis were implanted and fixed after the lesion resection. The examinations including general situation, cranio-maxillofacial structure and function were taken during and after surgery to assess its using effect. Results: Ten patients [6 females and 4 males, (43.2±13.6) years old] were included and all prostheses were positioned accurately and fixed excellently. After (29.4±17.3) months follow-up, the occlusion relationship was stable and no adverse symptoms such as dizziness, headache, meningeal irritation and permanent facial nerve injury occurred. The pain, diet, mandibular movement function, lateral movement to diseased side and mouth opening had significant improvements. The forward movement and lateral movement to normal side were not improved significantly. There were no prosthesis displacement, loosening and fracture in X-ray and CT postoperatively. With the pre and postoperative craniomaxillofacial model merging, the maximal implanted error was (0.52±0.17) mm for fossa and condyle and (1.62±0.26) mm for skull base and mandibular handle in surface deviation analysis. Conclusions: The custom-made TMJ-skull base combined prosthesis with customized design and 3D printing fabrication is safe, effective and precise in clinical application.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Overview of the Skull
The cranial vault surrounds and protects the brain and houses the middle and inner ear structures. This cavity is bounded superiorly by the rounded top of the skull, which...

