Related Experiment Video
Updated: Oct 28, 2025

High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Diagnostic Performance of Single-Photon Emission Computed Tomography/Computed Tomography in Aseptic Loosening: A
Zhan Peng1, Yukun Jia1, Jin Li1
1Department of Orthopaedic Surgery, Affiliated Baoan Hospital of Shenzhen, Southern Medical University, Shenzhen, People's Republic of China; Clinical Teaching Department, the Second School of Clinical Medicine, Southern Medical University, Shenzhen, People's Republic of China.
Background:
The aim of this study is to evaluate the diagnostic value and clinical applicability of single-photon emission computed tomography/computed tomography (SPECT/CT) in aseptic loosening (AL) of prostheses by meta-analysis.
Method:
Literature on the diagnostic value of SPECT/CT in AL of prostheses was obtained by computer and manual review. The quality of the included studies was evaluated according to the Quality Assessment Diagnostic Accuracy Studies 2. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and other indicators were calculated, and a forest map and summary receiver operating characteristic were drawn to calculate the area under the curve. Meta-regression analysis was performed to identify the sources of heterogeneity and corresponding subgroup analysis was performed. A Fagan plot, likelihood ratio point plot, and Deek's funnel plot were drawn and analyzed.
Results:
A total of 15 studies were included. The meta-analysis results showed that the pooled sensitivity and specificity of SPECT/CT for the diagnosis of aseptic prosthetic loosening were 0.94, 95% confidence interval [CI] (0.90-0.96) and 0.89, 95% CI (0.78-0.95), respectively while the pooled positive likelihood ratio and pooled negative likelihood ratio were 8.65, 95% CI (4.18-17.90) and 0.07, 95% CI (0.04-0.11), respectively. The pooled diagnostic odds ratio was 130.36, 95% CI (45.18-376.19), and the area under the curve was 0.97, 95% CI (0.95-0.98).
Conclusion:
As a diagnostic method for AL, SPECT/CT has high diagnostic sensitivity and specificity as well as high diagnostic efficiency. It has good clinical application value and should be a primary choice in the diagnosis of AL after joint replacement.
More Related Videos
18:40Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET