Physiological Responses During High-Intensity Interval Training in Young Swimmers
Related Experiment Video
Updated: Oct 28, 2025

A Swimming-Induced Zebrafish Exercise Apparatus for Versatile Training Approaches
Published on: October 18, 2024
Tiago André Freire Almeida1,2,3, Dalton Müller Pessôa Filho3,4, Mário Cunha Espada5,6
1Interdisciplinary Center for the Study of Human Performance (CIPER), Faculdade de Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal.
Abstract:
This study analyzed whether 100- and 200-m interval training (IT) in swimming differed regarding temporal, perceptual, and physiological responses. The IT was performed at maximal aerobic velocity (MAV) until exhaustion and time spent near to maximalVO2 peak oxygen uptake (⩒O2peak), total time limit (tLim), peak blood lactate [La-] peak, ⩒O2 kinetics (⩒O2K), and rate of perceived exertion (RPE) were compared between protocols. Twelve swimmers (seven males 16.1 ± 1.1 and five females 14.2 ± 1 years) completed a discontinuous incremental step test for the second ventilatory threshold (VT2), ⩒O2peak, and MAV assessment. The swimmers subsequently completed two IT protocols at MAV with 100- and 200-m bouts to determine the maximal ⩒O2 (peak-⩒O2) and time spent ≥VT2, 90, and 95% of ⩒O2peak for the entire protocols (IT100 and IT200) and during the first 800-m of each protocol (IT8x100 and IT4x200). A portable apparatus (K4b2) sampled gas exchange through a snorkel and an underwater led signal controlled the velocity. RPE was also recorded. The Peak-⩒O2 attained during IT8x100 and IT4x200 (57.3 ± 4.9 vs. 57.2 ± 4.6 ml·kg-1·min-1) were not different between protocols (p = 0.98) nor to ⩒O2peak (59.2 ± 4.2 ml·kg-1·min-1, p = 0.37). The time constant of ⩒O2K (24.9 ± 8.4 vs. 25.1 ± 6.3-s, p = 0.67) and [La-] peak (7.9 ± 3.4 and 8.7 ± 1.5 mmol·L-1, p = 0.15) also did not differ between IT100 and IT200. The time spent ≥VT2, 90, and 95%⩒O2peak were also not different between IT8x100 and IT4x200 (p = 0.93, 0.63, and 1.00, respectively). The RPE for IT8x100 was lower than that for IT4x200 (7.62 ± 2 vs. 9.5 ± 0.7, p = 0.01). Both protocols are considered suitable for aerobic power enhancement, since ⩒O2peak was attained with similar ⩒O2K and sustained with no differences in tLim. However, the fact that only the RPE differed between the IT protocols suggested that coaches should consider that nx100-m/15-s is perceived as less difficult to perform compared with nx200-m/30-s for the first 800-m when managing the best strategy to be implemented for aerobic power training.
Related Concept Videos
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Responses to Heat and Cold Stress
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...

