Related Experiment Video
Updated: Oct 27, 2025

Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Perioperative Anomalous Pulmonary Venous Return Evaluation With Low-Dose Cardiac Computed Tomography
Li Xiong1, Mehul D Patel1, Gurur Biliciler-Denktas1
1Division of Pediatric Cardiology, Department of Pediatrics, 12339University of Texas Health Science Center at Houston, TX, USA.
Background:
Low-dose multidetector computed tomographic angiography (MDCTA) is playing an increasingly larger role in the diagnosis of anomalous pulmonary venous return (APVR). Despite advances in new computed tomographic (CT) techniques with radiation dose reduction, there are limited studies describing radiation dose parameters to allow routine use of cardiac CT in infants and children with APVR. This study compares cardiac CT findings with intraoperative findings and describes comprehensive radiation exposure parameters.
Methods:
A retrospective analysis of 27 patients compared MDCTA and intraoperative or cardiac catheterization findings of the pulmonary venous anatomy.
Results:
A total of 32 MDCTA studies were performed on these 27 patients. Of the 28 studies with subsequent intervention, MDCTA accurately diagnosed the anomalous pulmonary venous anatomy in 27 (96.4%) patients. Narrowing of the pulmonary venous confluence entrance to the coronary sinus was missed on cardiac CT in one patient due to motion artifact, but it was noted intraoperatively. Median estimated effective radiation dose was 0.98 mSv (range: 0.39-3.2 mSv), and mean estimated effective radiation dose was 1.1 ± 0.68 mSv. Median total dose length product (DLP) was 25 mGy cm (range: 10-83 mGy cm), and mean total DLP was 28 ± 18 mGy cm. Median CTDI volume was 3.8 mGy (range: 2.5-14.6 mGy), and mean CTDI volume was 5.0 ± 3.2 mGy.
Conclusions:
We conclude that modern cardiac MDCTA is the best imaging modality to guide management in both preintervention and postintervention APVR patients. In this study, we describe comprehensive radiation exposure parameters in infants and children with APVR.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies