Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

5.3K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
5.3K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

1.1K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical, Public Health, and Microbiologic Factors all Suspected to Contribute to the Epidemiology of Disseminated Gonococcal Infections.

Clinical infectious diseases : an official publication of the Infectious Diseases Society of America·2026
Same author

Maximizing Lipidome Coverage of Mouse Liver Following the IV Administration of Gefitinib by Combining Both UHPLC-MS-Based Untargeted and Targeted Lipidomics.

Journal of proteome research·2026
Same author

Development and Validation of a Streamlined Workflow for Proteomic Analysis of Proteins and Post-translational Modifications from Dried Blood.

Journal of proteome research·2026
Same author

Reversing the great degradation of nature by reducing factors related to cropland expansion.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Serological response after shorter durations of therapy for syphilis of late latent or unknown duration: What does it mean?

Clinical infectious diseases : an official publication of the Infectious Diseases Society of America·2026
Same author

Metabolism and Excretion of Synthetic Extended Viperin Pathway Deoxydidehydronucleosides in the Sprague-Dawley Rat.

Journal of proteome research·2026
Same journal

Heterojunction-Enhanced Interfacial Evanescent-Tunable Fiber Optic Probe for Amplification-free CRISPR/Cas12a-Based Rapid and Ultrasensitive Detection of MPXV.

Analytical chemistry·2026
Same journal

Tunable Charge Transfer in Europium Metal-Organic Frameworks for Ratiometric Sensing of a Sarin Simulant.

Analytical chemistry·2026
Same journal

A β-Cyclodextrin/Ag<sub>2</sub>O@MWCNT-Based Stochastic Platform for the Simultaneous Molecular Enantiorecognition and Enantioanalysis of Twelve Amino Acids in Biological Matrices.

Analytical chemistry·2026
Same journal

The ACS at 150: The History of Analytical Chemistry Publications and a Century of Progress.

Analytical chemistry·2026
Same journal

Machine Learning-Enabled Image Analysis of Complex Chemical Mixtures: Synthetic Urine Droplets as a Test System.

Analytical chemistry·2026
Same journal

H<sub>2</sub>O<sub>2</sub>/Viscosity Tandem-Locked Fluorescent Probes Based on an In Situ Fluorophore Synthesis Strategy for Colitis Imaging and Diagnosis.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: Oct 27, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

22.9K

High-Throughput UHPLC/MS/MS-Based Metabolic Profiling Using a Vacuum Jacketed Column.

Robert S Plumb1, Thomas McDonald2, Paul D Rainville1

  • 1Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States.

Analytical Chemistry
|July 19, 2021
PubMed
Summary
This summary is machine-generated.

Vacuum jacketed column (VJC) technology significantly reduces band broadening in ultra-high-performance liquid chromatography (UHPLC) by mitigating frictional heating effects. This leads to improved metabolite profiling in urine with higher peak capacity and more confident identification.

More Related Videos

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.0K
Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
10:37

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification

Published on: November 15, 2017

12.2K

Related Experiment Videos

Last Updated: Oct 27, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

22.9K
Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.0K
Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
10:37

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification

Published on: November 15, 2017

12.2K

Area of Science:

  • Analytical Chemistry
  • Chromatography
  • Mass Spectrometry

Background:

  • Frictional heating in UHPLC columns causes band broadening due to radial and longitudinal temperature gradients.
  • These effects limit chromatographic resolution and metabolite identification confidence.
  • Conventional methods to mitigate band broadening include vacuum jacketing and controlled heating.

Purpose of the Study:

  • To evaluate the effectiveness of vacuum jacketed column (VJC) technology for metabolite profiling in urine.
  • To assess the impact of VJC on chromatographic performance, including peak width, tailing, and peak capacity.
  • To determine the benefits of VJC for mass spectrometry (MS) based metabolite identification.

Main Methods:

  • Application of VJC technology with a novel column housing near the mass spectrometer source.
  • Minimized tubing from the column outlet to the electrospray probe.
  • Reversed-phase gradient separation of urine metabolites using both conventional LC/MS and VJC systems.

Main Results:

  • VJC system reduced average peak widths from 1.2 s to 0.6 s for endogenous urine compounds.
  • Peak tailing factor decreased from 1.25 to 1.13, and peak capacity increased from 65 to 120.
  • A 25% increase in detected features, simplified MS/MS spectra, and 10-120% increase in MS peak response were observed with VJC.

Conclusions:

  • VJC technology effectively minimizes band broadening in UHPLC, enhancing chromatographic resolution.
  • The improved separation and detection capabilities of VJC facilitate more confident metabolite identification and improve MS data quality.
  • VJC offers significant advantages for sensitive and high-resolution metabolomics studies.