Related Experiment Video
Updated: Oct 27, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Biocompatibility Parameters with Standard and Increased Dose of Citrate in Hemodialysis-A Randomized Trial
Alesa Orsag1,2, Mojca Bozic-Mijovski3, Samo Hudoklin4
1Department of Nephrology, University Medical Center Ljubljana, 1000 Ljubljana, Slovenia.
Background:
The dose of citrate needed in regional citrate anticoagulation (RCA) to achieve optimal biocompatibility is unknown. We performed a randomized trial comparing two doses (ACTRN12613001340729).
Methods:
In 30 patients a single hemodialysis with either standard (2.7 mmol/L) or increased dose of citrate (4 mmol/L) was performed. C5a-desArg, myeloperoxidase (MPO), thrombin-antithrombin complex (TAT), and platelet factor 4 (PF4) were measured and the inner surface of the dialyzer fibers was evaluated with scanning electron microscopy (SEM).
Results:
A good separation of anticoagulation effect was achieved (post-filter ionized calcium 0.20 vs. 0.31 mmol/L, p < 0.05). There was no effect of citrate dose on any of the biocompatibility parameters; transient and parallel increase in PF4 after 30 min and parallel increase in TAT after 4 h were observed. There were no visually detected clotting problems within the circuit and no significant hypocalcemia in either group. SEM clotting score was excellent and comparable in both groups (p = 0.59).
Conclusions:
Given the excellent results in both groups, absence of between group differences and inability of the increased dose of citrate to completely blunt the small residual increase in PF4 and TAT, we conclude that the standard dose of citrate seems sufficient in RCA for chronic hemodialysis.
More Related Videos
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Bioavailability Study Design: Healthy Subjects Versus Patients
Hemodialysis II: Procedure and Complications
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration