Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Oct 27, 2025

Optimized and Simplified Technique for the Production and Culture of Precision-Cut Liver Slices
06:00

Optimized and Simplified Technique for the Production and Culture of Precision-Cut Liver Slices

Published on: November 22, 2024

1.0K

Best Practices and Progress in Precision-Cut Liver Slice Cultures.

Liza Dewyse1, Hendrik Reynaert2, Leo A van Grunsven1

  • 1Liver Cell Biology Research Group, Department of Basic Biomedical Sciences, Vrije Universiteit Brussel, 1090 Brussels, Belgium.

International Journal of Molecular Sciences
|July 20, 2021
PubMed
Summary

Precision-cut liver slices (PCLS) offer a 3D in vitro model for liver disease research. This review evaluates if PCLS limitations, like induced fibrosis, have been overcome since their 1985 invention.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

1q gain bypasses the selective barrier against aneuploidy in RPE differentiation via wild-type co-culture rescue.

Nature communications·2025
Same author

Clinical Trial: Hepatitis B Virus Genotype and a Combination of End-of-Treatment Biomarkers Predict Severe Flares After Nucleos(t)ide Analogue Cessation.

Alimentary pharmacology & therapeutics·2025
Same author

9-cis-Retinoic Acid Improves Disease Modelling in iPSC-Derived Liver Organoids.

Cells·2025
Same author

Loss of endothelial ZEB2 in mice attenuates steatosis early during metabolic dysfunction-associated steatotic liver disease.

Scientific reports·2025
Same author

Steatotic liver disease induces YAP/TAZ-driven cell competition that can suppress tumor initiation.

Journal of hepatology·2025
Same author

Co-existing regeneration mechanisms in severe alcohol-related steatohepatitis.

Translational gastroenterology and hepatology·2025

Area of Science:

  • Hepatology
  • In vitro toxicology
  • Liver disease modeling

Background:

  • Precision-cut liver slices (PCLS) were introduced 35 years ago as a promising in vitro model for liver research.
  • PCLS retain complex 3D liver structures and cell-cell/cell-matrix interactions, mimicking the in vivo environment.
  • A key limitation of PCLS is the procedure-induced fibrotic response.

Purpose of the Study:

  • To review the parameters and potential of PCLS cultures for liver disease research.
  • To critically evaluate if the initial limitations and pitfalls of PCLS have been addressed.
  • To summarize recent advances and assess the progress of PCLS use since 1985.

Main Methods:

  • Literature review of PCLS research.
  • Analysis of PCLS culture parameters and their impact.
Keywords:
3DPCLSchronic liver diseasein vitro liver

More Related Videos

Murine Precision-Cut Liver Slices as an Ex Vivo Model of Liver Biology
12:36

Murine Precision-Cut Liver Slices as an Ex Vivo Model of Liver Biology

Published on: March 14, 2020

16.7K
Rat Liver Perfusion and Primary Hepatocytes Isolation: An Old Procedure Crucial for Cutting-Edge 3D Organoids Culture
13:09

Rat Liver Perfusion and Primary Hepatocytes Isolation: An Old Procedure Crucial for Cutting-Edge 3D Organoids Culture

Published on: November 22, 2024

1.5K

Related Experiment Videos

Last Updated: Oct 27, 2025

Optimized and Simplified Technique for the Production and Culture of Precision-Cut Liver Slices
06:00

Optimized and Simplified Technique for the Production and Culture of Precision-Cut Liver Slices

Published on: November 22, 2024

1.0K
Murine Precision-Cut Liver Slices as an Ex Vivo Model of Liver Biology
12:36

Murine Precision-Cut Liver Slices as an Ex Vivo Model of Liver Biology

Published on: March 14, 2020

16.7K
Rat Liver Perfusion and Primary Hepatocytes Isolation: An Old Procedure Crucial for Cutting-Edge 3D Organoids Culture
13:09

Rat Liver Perfusion and Primary Hepatocytes Isolation: An Old Procedure Crucial for Cutting-Edge 3D Organoids Culture

Published on: November 22, 2024

1.5K
  • Critical evaluation of PCLS advancements and remaining challenges.
  • Main Results:

    • PCLS offer a superior in vitro model due to their preserved 3D architecture and cell interactions.
    • The procedure-induced fibrotic response remains a significant challenge for PCLS models.
    • Significant progress has been made in PCLS research, though challenges persist.

    Conclusions:

    • PCLS remain a valuable tool for studying liver disease in vitro, offering a more physiologically relevant model.
    • Addressing the fibrotic response is crucial for maximizing the reliability of PCLS.
    • Continued research and refinement are essential for the optimal application of PCLS in liver research.