A novel speed control strategy for 3-phase induction motor drives with star-connected under single-phase open-circuit
Rahemeh Tabasian1, Mahmood Ghanbari1, Abdolreza Esmaeli2
1Department of Electrical Engineering, Gorgan Branch, Islamic Azad University, Gorgan, Iran.
Abstract:
In this research, a novel control method is proposed for 3-Phase Induction Motor (3-PIM) drives with star-connected under Single-Phase Open-Circuit (SPOC) fault using modified Rotor Field-Oriented Control (RFOC) strategy. The standard RFOC strategy is designed based on the d-q model of 3-PIM during normal mode. This strategy cannot be applied for a 3-PIM under SPOC fault as the model of a healthy 3-PIM is different from the model of a faulty 3-PIM. The use of standard RFOC strategy for Vector Control (VC) of a 3-PIM under SPOC fault increases the electromagnetic torque ripples during this fault. To overcome this problem, two unbalanced rotational transformations are used. A Current Transformation Matrix (CTM) is obtained based on the concept of maintaining value of Magnetic Motive Force (MMF) of the faulted machine like the healthy machine. Then, a Voltage Transformation Matrix (VTM) is introduced by using the presented CTM and according to the Single-Phase Induction Motor (SPIM) model. Based on the results, faulted machine RFOC equations were obtained similar to the healthy machine RFOC equations by using the CTM and VTM. The proposed technique was verified by simulations and experiments. Results indicated that the performances of the faulted machine under the proposed RFOC strategy are better than standard control techniques.
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Three-Phase Circuits