Related Experiment Video
Updated: Oct 27, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
An Analysis of Frequency of Continuous Blood Pressure Variation and Haemodynamic Responses during Haemodialysis
Venkata R Latha Gullapudi1,2, Kelly White3, Jill Stewart4
1Centre for Kidney Research and Innovation, Academic unit for Translational Medical Sciences, School of Medicine, University of Nottingham, Nottingham, United Kingdom.
Background:
Higher beat-to-beat blood pressure (BP) variation during haemodialysis (HD) has been shown to be associated with elevated cardiac damage markers and white matter ischaemic changes in the brain suggesting relevance to end-organ perfusion. We aimed to characterize individual patterns of BP variation and associated haemodynamic responses to HD.
Methods:
Fifty participants underwent continuous non-invasive haemodynamic monitoring during HD and BP variation were assessed using extrema point (EP) frequency analysis. Participants were divided into those with a greater proportion of low frequency (LF, n = 21) and high frequency (HF, n = 22) of BP variation. Clinical and haemodynamic data were compared between groups.
Results:
Median EP frequencies for mean arterial pressure (MAP) of mid-week HD sessions were 0.54 Hz (interquartile range 0.18) and correlated with dialysis vintage (r = 0.32, p = 0.039), NT pro-BNP levels (r = 0.32, p = 0.038), and average real variability (ARV) of systolic BP (r = 0.33, p = 0.029), ARV of diastolic BP (r = 0.46, p = 0.002), and ARV of MAP (r = 0.57, p < 0.001). In the LF group, MAP positively correlated with cardiac power index (CPI) in each hour of dialysis, but not with total peripheral resistance index (TPRI). In contrast, in the HF group, MAP correlated with TPRI in each hour of dialysis but only with CPI in the first hour.
Conclusions:
EP frequency analysis of continuous BP monitoring during dialysis allows assessment of BP variation and categorization of individuals into low- or high-frequency groups, which were characterized by different haemodynamic responses to dialysis. This may assist in improved individualization of dialysis therapy.
Related Concept Videos
Hemodialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Continuous Renal Replacement Therapy
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis