Related Experiment Video
Updated: Oct 27, 2025

Therapy Interventions for Upper Limb Amputees Undergoing Selective Nerve Transfers
Published on: October 29, 2021
[Translation, Adaptation, Reliability and Validity of the German Version of the Prosthesis Mobility Questionnaire 2.0
Alexander Ranker1, Marcus Örgel2, Jörg Schiller1
1Klinik für Rehabilitationsmedizin, Medizinische Hochschule Hannover.
Purpose:
The aim of this prospective validation study was to translate the Prosthesis Mobility Questionnaire 2.0 (PMQ) into German based on a guideline, following by psychometric testing for its validity and reliability using classical test theory.
Methods:
The PMQ was translated into German according to ISPOR guidelines using double forward and double backward translations, finalized by pilot testing (N=10). Subsequently, assessment of the validity and reliability was performed from March 2020 to August 2020 on N=61 patients with unilateral lower limb amputation. Construct validity was determined by using the German version of the Locomotor Capabilities Index-5 (LCI-5-D), the Rivermead Mobility Index (RMI), the Timed up and go Test (TUG), and K-levels. Cronbach's alpha was calculated to check internal consistency and discriminatory power was determined by item correlations. Test-retest reliability was calculated using ICC (2,1). Based on the ICC, the minimum detectable difference (MDC) was calculated.
Results:
The translation process required small changes after the pilot test. The validation study was performed on N=61 patients (56.59±13.16 years, m/f=38/23). A mean PMQ of 26.23±8.89 points was achieved. Ceilings or floor effects for total score did not appear. Construct validity showed strong positive correlations to LCI-5-D (r=0.74, p<0.001), RMI (r=0.63 p<0.001) as well as k-levels (r=0.61 p<0.001) and moderate negative correlation to TUG (r=- 0.49, p<0.001). Internal consistency was excellent with Cronbach's alpha=0.95). All items showed a value greater than r=0.40 for item-to-total score correlation. Test-retest reliability was excellent with an ICC (2,1)=0.98 with a timespan between T0 and T1 of 3.2±2.83 days. Based on this results, the MDC was 3.40 points.
Conclusion:
The German version of the Prosthesis Mobility Questionnaire 2.0 is a valid, reliable patient reported outcome measure (PROM) for measuring mobility and functional ability of patients with exoprosthesis due to unilateral lower limb amputation. It can be used for a German-speaking population.