Intraindividual Doppler Flow Response to Exercise Differs Between Symptomatic and Asymptomatic Achilles Tendons

Lucie Risch1, Josefine Stoll1, Anne Schomöller1

  • 1University Outpatient Clinic, Sports Medicine and Orthopedics, University of Potsdam, Potsdam, Germany.

Summary

Running exercise increases intratendinous blood flow (IBF) in Achilles tendons, particularly in symptomatic tendons with tendinopathy. This response suggests altered neovascularization associated with pain in Achilles tendinopathy.

Related Concept Videos

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
97
Exercise and Cardiovascular Response01:20

Exercise and Cardiovascular Response

Exercise significantly impacts cardiovascular response, which is crucial for understanding patient health and designing effective treatment plans.
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
2.4K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.7K
Cardiovascular System Abnormal Findings I: Inspection and Palpation01:29

Cardiovascular System Abnormal Findings I: Inspection and Palpation

In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
592