Short-Term Repeatability of in Vivo Cardiac Intravoxel Incoherent Motion Tensor Imaging in Healthy Human Volunteers
Xiu-Shi Zhang1, En-Hui Liu1, Xin-Yu Wang1
1Imaging Center, Harbin Medical University Cancer Hospital, Harbin, China.
Background:
Intravoxel incoherent motion (IVIM) tensor imaging is a promising technique for diagnosis and monitoring of cardiovascular diseases. Knowledge about measurement repeatability, however, remains limited.
Purpose:
To evaluate short-term repeatability of IVIM tensor imaging in normal in vivo human hearts.
Study Type:
Prospective.
Population:
Ten healthy subjects without history of heart diseases.
Field Strength/Sequence:
Balanced steady-state free-precession cine sequence and single-shot spin-echo echo planar IVIM tensor imaging sequence (9 b-values, 0-400 seconds/mm2 and six diffusion-encoding directions) at 3.0 T.
Assessment:
Subjects were scanned twice with an interval of 15 minutes, leaving the scanner between studies. The signal-to-noise ratio (SNR) was evaluated in anterior, lateral, septal, and inferior segments of the left ventricle wall. Fractional anisotropy (FA), mean diffusivity (MD), mean fraction (MF), and helix angle (HA) in the four segments were independently measured by five radiologists.
Statistical Tests:
IVIM tensor indexes were compared between observers using a one-way analysis of variance or between scans using a paired t-test (normal data) or a Wilcoxon rank-sum test (non-normal data). Interobserver agreement and test-retest repeatability were assessed using the intraclass correlation coefficient (ICC), within-subject coefficient of variation (WCV), and Bland-Altman limits of agreements.
Results:
SNR of inferior segment was significantly lower than the other three segments, and inferior segment was therefore excluded from repeatability analysis. Interobserver repeatability was excellent for all IVIM tensor indexes (ICC: 0.886-0.972; WCV: 0.62%-4.22%). Test-retest repeatability was excellent for MD of the self-diffusion tensor (D) and MF of the perfusion fraction tensor (fp ) (ICC: 0.803-0.888; WCV: 1.42%-9.51%) and moderate for FA and MD of the pseudo-diffusion tensor (D* ) (ICC: 0.487-0.532; WCV: 6.98%-10.89%). FA of D and fp and HA of D presented good test-retest repeatability (ICC: 0.732-0.788; WCV: 3.28%-8.71%).
Data Conclusion:
The D and fp indexes exhibited satisfactory repeatability, but further efforts were needed to improve repeatability of D* indexes.
Level Of Evidence:
2 TECHNICAL EFFICACY: Stage 1.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...