Cross-Normalization of MALDI Mass Spectrometry Imaging Data Improves Site-to-Site Reproducibility
Tobias Boskamp1,2, Rita Casadonte3, Lena Hauberg-Lotte2
1Bruker Daltonics GmbH & Co. KG, 28359 Bremen, Germany.
Abstract:
Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) is an established tool for the investigation of formalin-fixed paraffin-embedded (FFPE) tissue samples and shows a high potential for applications in clinical research and histopathological tissue classification. However, the applicability of this method to serial clinical and pharmacological studies is often hampered by inevitable technical variation and limited reproducibility. We present a novel spectral cross-normalization algorithm that differs from the existing normalization methods in two aspects: (a) it is based on estimating the full statistical distribution of spectral intensities and (b) it involves applying a non-linear, mass-dependent intensity transformation to align this distribution with a reference distribution. This method is combined with a model-driven resampling step that is specifically designed for data from MALDI imaging of tryptic peptides. This method was performed on two sets of tissue samples: a single human teratoma sample and a collection of five tissue microarrays (TMAs) of breast and ovarian tumor tissue samples (N = 241 patients). The MALDI MSI data was acquired in two labs using multiple protocols, allowing us to investigate different inter-lab and cross-protocol scenarios, thus covering a wide range of technical variations. Our results suggest that the proposed cross-normalization significantly reduces such batch effects not only in inter-sample and inter-lab comparisons but also in cross-protocol scenarios. This demonstrates the feasibility of cross-normalization and joint data analysis even under conditions where preparation and acquisition protocols themselves are subject to variation.
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...