Is a higher sampling rate desirable in the computer processing of the pediatric electrocardiogram?
Related Experiment Video
Updated: Oct 23, 2026

High Density Event-related Potential Data Acquisition in Cognitive Neuroscience
Published on: April 16, 2010
H Yamamoto1, H Miyahara, A Domae
1Department of Internal Medicine, School of Medicine, Kitasato University, Kanagawa, Japan.
Abstract:
A considerably large number of ECGs of pediatric patients had small notches and slurs on QRS complexes. By sampling these ECGs at higher rates, namely 4 KHz, it was shown that the higher rate data accurately reconstructed the notches and slurs on the QRS complex which were occasionally missed or distorted when the sampling rate was 250 Hz. When using the sampling rate of 250 Hz, it was observed that the reduction of the peak-to-peak amplitude of a QRS complex exceeded 0.1 mV in nearly 30 percent of tested cases, even if the ECG did not contain unwanted noise signals. Moreover, if there is relatively more noise in children's ECGs, one should reduce noise in such data in order to prevent measurement errors in the succeeding steps of the computer program. In such circumstances, the higher sampling rate would be preferable since filtering techniques which are used to reduce noise may considerably affect the estimation of the onset, offset and amplitude of the intrinsic ECG signals if the sampling rate is low. The reduction of the price of computers and their peripheral devices may facilitate the adoption of the higher sampling rate. From these considerations it was concluded that the use of the higher sampling rate might be both practical and an effective measure to enhance the diagnostic performance of the computer ECG systems.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Sampling Theorem
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Upsampling
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...