Related Experiment Video
Updated: Oct 27, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Glucose Regulation Beyond HbA1c in Type 2 Diabetes Treated With Insulin: Real-World Evidence From the DIALECT-2
Niala den Braber1,2, Miriam M R Vollenbroek-Hutten3,2, Kathryn M Westerik3
1Division of Nephrology, Department of Internal Medicine, Ziekenhuisgroep Twente, Almelo and Hengelo, the Netherlands n.braber@zgt.nl.
Objective:
To investigate glucose variations associated with glycated hemoglobin (HbA1c) in insulin-treated patients with type 2 diabetes.
Research Design And Methods:
Patients included in Diabetes and Lifestyle Cohort Twente (DIALECT)-2 (n = 79) were grouped into three HbA1c categories: low, intermediate, and high (≤53, 54-62, and ≥63 mmol/mol or ≤7, 7.1-7.8, and ≥7.9%, respectively). Blood glucose time in range (TIR), time below range (TBR), time above range (TAR), glucose variability parameters, day and night duration, and frequency of TBR and TAR episodes were determined by continuous glucose monitoring (CGM) using the FreeStyle Libre sensor and compared between HbA1c categories.
Results:
CGM was performed for a median (interquartile range) of 10 (7-12) days/patient. TIR was not different for low and intermediate HbA1c categories (76.8% [68.3-88.2] vs. 76.0% [72.5.0-80.1]), whereas in the low category, TBR was higher and TAR lower (7.7% [2.4-19.1] vs. 0.7% [0.3-6.1] and 8.2% [5.7-17.6] vs. 20.4% [11.6-27.0], respectively, P < 0.05). Patients in the highest HbA1c category had lower TIR (52.7% [40.9-67.3]) and higher TAR (44.1% [27.8-57.0]) than the other HbA1c categories (P < 0.05), but did not have less TBR during the night. All patients had more (0.06 ± 0.06/h vs. 0.03 ± 0.03/h; P = 0.002) and longer (88.0 [45.0-195.5] vs. 53.4 [34.4-82.8] minutes; P < 0.001) TBR episodes during the night than during the day.
Conclusions:
In this study, a high HbA1c did not reduce the occurrence of nocturnal hypoglycemia, and low HbA1c was not associated with the highest TIR. Optimal personalization of glycemic control requires the use of newer tools, including CGM-derived parameters.
More Related Videos
08:13Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test OGTT and Insulin Tolerance Test ITT
Published on: January 7, 2018
10:35Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo
Published on: April 6, 2022
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Symptoms, Diagnosis, and Complications
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...