Related Experiment Video
Updated: Oct 26, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Cardiac Output Assessments in Anesthetized Children: Dynamic Capnography Versus Esophageal Doppler
Jacob Karlsson1,2, Anders Svedmyr1,2, Marion Wiegele3
1From the Department of Physiology and Pharmacology, Karolinska Institute, Stockholm, Sweden.
Background:
The objective of this study was to compare esophageal Doppler cardiac output (COEDM) against the reference method effective pulmonary blood flow cardiac output (COEPBF), for agreement of absolute values and ability to detect change in cardiac output (CO) in pediatric surgical patients. Furthermore, the relationship between these 2 methods and noninvasive blood pressure (NIBP) parameters was evaluated.
Methods:
Fifteen children American Society of Anesthesiology (ASA) I and II (median age, 8 months; median weight, 9 kg) scheduled for surgery were investigated in this prospective observational cohort study. Baseline COEPBF/COEDM/NIBP measurements were made at positive end-expiratory pressure (PEEP) 3 cm H2O. PEEP was increased to 10 cm H2O and COEPBF/COEDM/NIBP was recorded after 1 and 3 minutes. PEEP was then lowered to 3 cm H2O, and all measurements were repeated after 3 minutes. Finally, 20-µg kg-1 intravenous atropine was given with the intent to increase CO, and all measurements were recorded again after 5 minutes. Paired recordings of COEDM and COEPBF were examined for agreement and trending ability, and all parameters were analyzed for their responses to the hemodynamic challenges.
Results:
Bias between COEDM and COEPBF (COEDM - COEPBF) was -17 mL kg-1 min-1 (limits of agreement, -67 to +33 mL kg-1 min-1) with a mean percentage error of 32% (95% confidence interval [CI], 25-37) and a concordance rate of 71% (95% CI, 63-80). The hemodynamic interventions caused by PEEP manipulations resulted in significant decrease in COEPBF absolute numbers (155 mL kg-1 min-1 [95% CI, 151-159] to 127 mL kg-1 min-1 [95% CI, 113-141]) and a corresponding relative decrease of 18% (95% CI, 14-22) 3 minutes after application of PEEP 10. No corresponding decreases were detected by COEDM. Mean arterial pressure showed a relative decrease with 5 (95% CI, 2-8) and 6% (95% CI, 2-10) 1 and 3 minutes after the application of PEEP 10, respectively. Systolic arterial pressure showed a relative decrease of 5% (95% CI, 2-10) 3 minutes after application of PEEP 10. None of the recorded parameters responded to atropine administration except for heart rate that showed a 4% relative increase (95% CI, 1-7, P = .02) 5 minutes after atropine.
Conclusions:
COEDM was unable to detect the reduction of CO cause by increased PEEP, whereas COEPBF and to a minimal extent NIBP detected these changes in CO. The ability of COEPBF to react to minor reductions in CO, before noticeable changes in NIBP are seen, suggests that COEPBF may be a potentially useful tool for hemodynamic monitoring in mechanically ventilated children.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...