Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
Sensitivity Limits for in vivo ELISA Measurements of Molecular Biomarker Concentrations
John B Weaver1,2,3, Yinpeng Shi1, Dylan B Ness1
1Department of Radiology, Dartmouth-Hitchcock Medical Center and the Geisel School of Medicine, Dartmouth College, Hanover, NH, USA.
Abstract:
The extremely high sensitivity that has been suggested for magnetic particle imaging has its roots in the unique signal produced by the nanoparticles at the frequencies of the harmonics of the drive field. That sensitivity should be translatable to other methods that utilize magnetic nanoparticle probes, specifically towards magnetic nanoparticle spectroscopy that is used to measure molecular biomarker concentrations for an "in vivo ELISA" assay approach. In this paper, we translate the predicted sensitivity of magnetic particle imaging into a projected sensitivity limit for in vivo ELISA. The simplifying assumptions adopted are: 1) the limiting noise in the detection system is equivalent to the minimum detectable mass of nanoparticles; 2) the nanoparticle's signal arising from Brownian relaxation is completely eliminated by the molecular binding event, which can be accomplished by binding the nanoparticle to something so massive that it can no longer physically rotate and is large enough that Neel relaxation is minimal. Given these assumptions, the equation for the minimum concentration of molecular biomarker we should be able to detect is obtained and the in vivo sensitivity is estimated to be in the attomolar to zeptomolar range. Spectrometer design and nonspecific binding are the technical limitations that need to be overcome to achieve the theoretical limit presented.
More Related Videos
08:28Validated Immunochemical Assay for Comprehensive Determination of the Human Epidermal Growth Factor Receptor 2 Released from and Bound to Cells
Published on: May 9, 2025
14:48Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method
Published on: July 6, 2012
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...