Related Experiment Video
Updated: Oct 26, 2025

09:43
Analyses of Proteinuria, Renal Infiltration of Leukocytes, and Renal Deposition of Proteins in Lupus-prone MRL/lpr Mice
Published on: June 8, 2022
3.2K
Successful Urine Multiplex Bead Assay to Measure Lupus Nephritis Activity
Ellen M Cody1, Michael R Bennett1,2, Gaurav Gulati3
1Department of Pediatric Nephrology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
Kidney International Reports
|July 26, 2021
Summary
The Renal Activity Score for Lupus (RAIL) using 4 urinary biomarkers measured by multiplex assay shows good agreement with ELISA, suggesting a convenient method for assessing lupus nephritis activity. This approach may simplify diagnosis and therapy evaluation for lupus nephritis patients.
Area of Science:
- Nephrology
- Immunology
- Biomarker Discovery
Background:
- Lupus nephritis (LN) diagnosis and therapy monitoring are challenged by a lack of effective laboratory tests.
- Previously identified 6 urinary biomarkers (NGAL, KIM-1, MCP-1, adiponectin, hemopexin, ceruloplasmin) show high sensitivity and specificity for active LN.
- The Renal Activity Score for Lupus (RAIL) was developed using these biomarkers measured by ELISA.
Purpose of the Study:
- To evaluate the performance of the RAIL score using urinary biomarkers measured by a bead multiplex method (LUMINEX) compared to ELISA.
- To determine if the multiplex bead method is a viable and comparable alternative for clinical utility.
Main Methods:
- Assayed 341 urine samples from 46 patients with or without LN using both ELISA and LUMINEX multiplex assays.
- Assessed agreement between biomarker quantities and RAIL scores using correlation coefficients, Bland-Altman analysis, and regression.
- Focused on NGAL, KIM-1, MCP-1, and adiponectin due to successful measurement by LUMINEX.
Main Results:
- LUMINEX successfully measured NGAL, KIM-1, MCP-1, and adiponectin, but not ceruloplasmin and hemopexin.
- Good agreement was observed for RAIL scores derived from these 4 biomarkers, regardless of assay method (ICC = 0.78).
- RAIL scores using 4 biomarkers strongly correlated with scores using all 6 biomarkers (ICC = 0.97).
Conclusions:
- The LUMINEX platform enables convenient, simultaneous measurement of 4 key RAIL biomarkers.
- RAIL scores based on these 4 biomarkers are sufficient for accurately assessing LN activity.
- This multiplex approach offers a promising enhancement for the clinical utility of RAIL in lupus nephritis management.

