Related Experiment Video
Updated: Oct 26, 2025

A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
Characteristics and Safety of CO2 for the Fire Prevention Technology with Gob-Side Entry Retaining in Goaf
Junhong Si1, Lin Li1, Genyin Cheng1
1School of Emergency Technology and Management, North China Institute of Science and Technology, Beijing 101601, China.
Abstract:
The mining technology of gob-side entry retaining without a coal pillar is gradually becoming a mature and increasingly important mining technology. As it maintains the roadway near goaf, the air leakage should be greater than a U-type ventilation system in goaf, so it is prone to cause coal spontaneous combustion problems. CO2 is an inert gas, and it is usually used to prevent spontaneous combustion and extinguish coal fire. However, there is a lack of research on characteristics and safety of CO2 for the mining technology of gob-side entry retaining without the coal pillar. In this paper, the indexes of influencing factors were proposed on gas, pipelines, and mining technical parameters. Using a three-dimensional physical model of coal stope, the gas migration law of CO2, the relationship between gas injection rate and the oxidation zone area, and the safety of the CO2 inerting technology were analyzed. The results indicate that the O2 concentration is diluted between the working face and the injection port, especially in the air intake side. Furthermore, the CO2 injection rate is an important parameter to the fire prevention and extinguishing technology. When the gas injection rate ranges from 240 to 720 m3/h, the oxidation zone area varies from 7380 to 14 760 m2, and the gas injection rate grows exponentially with the area of the oxidation zone. Moreover, the redundant CO2 gas flows to the retaining roadway, and it reduces the O2 concentration, resulting in asphyxia accidents of miners. The research results are helpful to balance the relationship between inert gas injection and production safety and provide guidance for the practical application of the inert gas fire prevention technology.
Related Concept Videos
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...