Related Experiment Video
Updated: Oct 26, 2025

Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
Evaluation of the airway mechanics of modified toggle laryngoplasty constructs using a vacuum chamber airflow model
Sarah M Gray1, Santiago D Gutierrez-Nibeyro1, Laurent L Couëtil2
1Department of Clinical Veterinary Medicine, College of Veterinary Medicine, University of Illinois, Urbana-Champaign, Illinois, USA.
Objective:
To evaluate the airway mechanics of modified toggle LP constructs in an airflow chamber model and compare these to the airway mechanics of standard LP constructs.
Study Design:
Ex-vivo experimental study.
Sample Population:
Fifty-one equine cadaveric larynges.
Methods:
Bilateral LP constructs were performed using a modified toggle (n = 23) or a standard (n = 21) LP technique. Constructs were tested in an airflow model before and after cyclic loading which was designed to mimic postoperative swallowing. The cross-sectional area (CSA), peak translaryngeal airflow (L/s), and impedance (cmH2 0/L/s) were determined and compared between LP constructs before and after cycling.
Results:
The mean CSA of the rima glottidis of the modified toggle LP constructs was 15.2 ± 2.6 cm2 before and 14.7 ± 2.6 cm2 after cyclic loading, and the mean CSA of the rima glottidis of the standard LP constructs was 16.4 ± 2.9 cm2 before and 15.7 ± 2.8 cm2 after cyclic loading. The modified toggle LP constructs had similar peak translaryngeal impedance before and after cyclic loading (p = .13); however, the standard LP constructs had higher peak translaryngeal impedance after cyclic loading (p = .02).
Conclusion:
The modified toggle and standard LP constructs had comparable airway mechanics in an ex-vivo model.
Clinical Significance:
Further investigation is warranted to determine the extent to which the modified toggle LP technique restores normal airway function in horses with RLN.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...

