Related Experiment Video
Updated: Oct 26, 2025

Use of Galleria mellonella as a Model Organism to Study Legionella pneumophila Infection
Published on: November 22, 2013
Atmospheric dispersion and transmission of Legionella from wastewater treatment plants: A 6-year case-control study
L C Vermeulen1, P S Brandsema1, J van de Kassteele1
1National Institute for Public Health and the Environment (RIVM), the Netherlands.
Abstract:
Legionnaires Disease incidence has risen in the Netherlands in recent years. For the majority of the cases, the source of infection is never identified. Two Dutch wastewater treatment plants (WWTPs) have previously been identified as source of outbreaks of Legionnaires Disease (LD) among local residents. The objective of this study is to examine if LD patients in the Netherlands are more exposed to aerosols originating from WWTPs than controls.
Methods:
An atmospheric dispersion model was used to generate nationwide exposure maps of aerosols from 776 WWTPs in the Netherlands. Municipal sewage treatment plants and industrial WWTPs were both included. Exposure of LD cases and controls at the residential address was compared, in a matched case-control design using a conditional logistic regression. Cases were notified LD cases with onset of disease in the period 2013-2018 in the Netherlands (n = 1604).
Results:
Aerosols dispersed over a large part of the Netherlands, but modelled concentrations are estimated to be elevated in close proximity to WWTPs. A statistically significant association was found between LD and the calculated annual average aerosol concentrations originating from WWTPs (odds-ratio: 1.32 (1.06-1.63)). This association remained significant when the two outbreak-related WWTPs were removed from the analysis (odds-ratio: 1.28 (1.03-1.58)).
Conclusion:
LD cases were more exposed to aerosols from WWTPs than controls. This indicates that exposure to aerosols dispersed from WWTPs caused Legionnaires Disease in residents living near WWTPs in the period 2013-2018. In order to investigate which characteristics of WWTPs are associated with an increased LD risk, the WWTP database should be updated and more data is needed on the presence and survival of aerosolized Legionella bacteria to improve the Legionella dispersion modelling. Furthermore, it is recommended to further investigate how aerosol dispersion of WWTPs can effectively be reduced in order to reduce the potential health risk.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...

