Related Experiment Video
Updated: Oct 26, 2025

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Monolith/aminated graphene oxide composite-based electric field-assisted solid phase microextraction for efficient
Jiangyi Wu1, Hexun Chen1, Xiaojia Huang1
1Key Laboratory of the Ministry of Education for Coastal and Wetland Ecosystems; Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies; College of the Environment and Ecology, P. O. Box 1009, Xiamen University, Xiamen 361005, China.
Abstract:
Efficient capture of strongly polar, ionizable and trace phenoxycarboxylic acids herbicides (PCAHs) from aqueous samples is essential and challenging for environmental monitoring. In the present work, electric field-assisted solid-phase microextraction (EFA-SPME) based on monolith/aminated graphene oxide composite was developed for the first time to efficiently extract trace PCAHs prior to HPLC-tandem mass spectrometry (HPLC-MS/MS) quantification. First, poly (1-allyl-3-methylimidazole difluoromethanesulfonylamide salt-co-divinylbenzene/ethylene dimethacrylate) monolith/aminated graphene oxide composite (MAC) was prepared on the surface of stainless steel wire and employed as the extraction phase of SPME. After that, the MAC-based fiber and a stainless steel wire were connected to a DC power supply that allowed the implement of variable electric fields during adsorption and desorption processes. Various key factors influencing the extraction performance were inspected in detailed. Results well evidenced that the exertion of electric fields improved the enrichment performance, accelerated the trap and release procedures. The proposed MAC/EFA-SPME-HPLC-MS/MS method achieved wide linear ranges (0.005-50.0 μg/L), low limits of detection (0.54-1.3 ng/L) and good precision (2.7-7.0%) for the quantification of PCAHs. The related extraction mechanism was deduced. Additional, the current approach was successfully applied to monitor studied PCAHs at trace contents in environment waters, and the accuracy was confirmed by confirmatory experiments.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024