Related Experiment Video
Updated: Oct 26, 2025

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
An Ion Chromatography Method for Simultaneous Quantification of Chromate, Arsenate, Selenate, Perchlorate, and Other
Srivatsan Mohana Rangan1,2,3, Rosa Krajmalnik-Brown1,2,3, Anca G Delgado1,2,3
1School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, Arizona, USA.
Abstract:
Chromium (Cr) (VI) is a toxic, mutagenic, and carcinogenic water pollutant. The standard ion chromatography (IC) method for quantification of Cr (VI) in water samples is Environmental Protection Agency Method 218.7, which requires postcolumn derivatization with 1,5-diphenylcarbazide and UV-Vis spectroscopy detection. Method 218.7 is Cr (VI) specific; thus, it does not allow detection of co-occurring natural and anthropogenic anions in environmental media. In this study, we developed an isocratic IC method with suppressed conductivity detection, a Metrohm Metrosep A Supp 7 column, and sodium carbonate/acetonitrile as mobile phase for simultaneous quantification of Cr (VI), , As (V) as arsenate, Se (VI) as selenate, and the common anions F-, Cl-, , , and . The determination coefficient for every analyte was >0.99 and the method showed good accuracy in quantification. Cr (VI), As (V), Se (VI), and limit of detection and limit of quantification were 0.1-0.6 μg/L and 0.5-2.1 μg/L, respectively. Recovery of Cr (VI) in various aqueous samples (tap water, surface water, groundwater, and wastewater) was between 97.2% and 102.8%. Overall, most analytes showed acceptable recovery (80-120%) in the environmental samples tested. The IC method was applied to track Cr (VI) and other anion concentrations in laboratory batch microcosms experiments with soil, surface water, and anaerobic medium. The IC method developed in this study should prove useful to environmental practitioners, academic and research organizations, and industries for monitoring low concentrations of multiple anions in environmental media, helping to decrease the sample requirement, time, and cost of analysis.
More Related Videos
Related Concept Videos
Gravimetry: Inorganic And Organic Precipitating Agents
Ion-Exchange Chromatography
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Qualitative Analysis
For instance, group IV...
Precipitation and Co-precipitation
Extraction: Advanced Methods