Related Experiment Video
Updated: Oct 26, 2025

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Plugging Paravalvular Leak in Transcatheter Aortic Valves
Sean M Conte1, Katherine Kearney1, Pankaj Jain1
1Department of Cardiology, St. Vincent's Hospital Sydney, Darlinghurst, Australia.
Abstract:
Paravalvular leak can complicate transcatheter aortic valve replacement with important prognostic implications. Correction of defects requires complex planning and execution. Multiple or irregular lesions, calcified annulus, and high sealing skirts on self-expandable devices are especially challenging. Such defects may be approximated using malleable vascular closure devices. (Level of Difficulty: Intermediate.).
More Related Videos
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management