Related Experiment Video
Updated: Oct 26, 2025

06:04
Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
279
Correction of a Malpositioned Portico Transcatheter Aortic Valve Using a Snare Maneuver
Udaya Prashant Ponangi1, Sumit Yadav1, Virag Kushwaha2
1Townsville Hospital, Towsnville, Australia Department of Cardiology and Cardiothoracic Surgery, Douglas, Australia.
JACC. Case Reports
|July 28, 2021
Abstract:
A 75-year-old woman with severe aortic stenosis underwent transcatheter aortic valve replacement using a 23-mm self-expanding Portico valve (Abbott). After complete deployment, it was found to be unacceptably low, with significant paravalvular regurgitation. The valve was pulled upward to the correct position successfully by using the snare maneuver. (Level of Difficulty: Advanced.).

