Related Experiment Video
Updated: Oct 26, 2025

In vivo Macrophage Imaging Using MR Targeted Contrast Agent for Longitudinal Evaluation of Septic Arthritis
Published on: October 20, 2013
Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled
Marcel Prasetyo1, Ariel Elisa Mongan2, Novie Amelia Chozie3
1Department of Radiology, Faculty of Medicine, Universitas Indonesia - Dr. Cipto Mangunkusumo National Central General Hospital, Jl. Diponegoro No.71, Jakarta Pusat, DKI Jakarta, 10430, Indonesia. marcel71@ui.ac.id.
Background:
Repeated bleeding in hemophilic arthropathy (HA) may result in severe degenerative changes and joint destruction. The gradient-recalled echo (GRE) sequence MR is proved to be the best method to detect hemosiderin deposition. However, MR is not widely available in developing countries, including Indonesia. Some studies have proposed ultrasonography (US) as an alternative tool in evaluating hemophilic joint. However, there is still some disagreement on the ability of US to detect hemosiderin deposition.
Objective:
To evaluate the association between US and GRE-sequence MR imaging in detecting hemosiderin deposition in hemophilic ankle joint.
Material And Methods:
A total of 102 sites from 17 ankle joints of 11 boys with severe hemophilia A underwent US examination using a high-frequency linear array transducer. GRE-sequence MR examination was performed in sagittal view consistent with the sites scanned by US. Both examinations were performed on the same day, but MR interpretation was performed blindly at different times. The association between US and GRE-sequences in detecting hemosiderin deposition was analyzed using McNemar's test.
Results:
Statistical analysis showed a significant association (p value < 0.001) between US and GRE MR in detecting hemosiderin deposition, but the association is weak (R = 0.26). Sensitivity and specificity of US for detecting hemosiderin deposition were 46.84% (95%CI: 35.51-58.40) and 95.65% (95%CI: 78.05-99.89), respectively, with positive predictive value 97.37% (95%CI: 84.29-99.61), negative predictive value 34.38% (95%CI: 29.50-39.60) and accuracy 57.84% (95%CI: 47.66-67.56).
Conclusion:
There was a weak association between US and GRE-sequences in detecting hemosiderin deposition of hemophilic ankle joint. .
Related Concept Videos
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies