Peripheral thermometry: Agreement between non-touch infrared versus traditional modes in an adult population
Penelope Sweeting1, Minakshi Murphy1, Sadie Geraghty2
1College of Nursing and Midwifery, Charles Darwin University, Sydney, New South Wales, Australia.
Aim:
To test whether infrared non-touch forehead thermometry (FNTT) obtains comparable temperature readings in adults compared with common, non-invasive thermometry methods such as axillary (DAT), oral (DOT) and infrared tympanic (ITT).
Design:
A prospective, repeated-measures comparative diagnostic test study design was used for this study.
Methods:
Data were collected from a convenience sample of 169 nursing students over 3 months (March 2019 to May 2019). Participants had their temperature measured once with each of the four thermometers. Agreement between thermometers was assessed using repeated-measures analysis of variance with Bonferroni post hoc testing.
Results/Findings:
One hundred and sixty-one participants were included in the final analysis. A repeated-measures ANOVA showed statistically significant differences between the four thermometer temperature readings. Post hoc pairwise comparisons with Bonferroni adjustment revealed infrared non-touch forehead thermometry demonstrated statistically significant higher mean temperatures compared with digital oral thermometry MD = 0.466℃ (95% CI, 0.357-0.576, p < .001) and digital axillary thermometry MD = 0.897℃ (95% CI, 0.752-1.043, p < .001), but not with infrared tympanic MD = 0.069℃ (95% CI, -0.025-0.162, p = .307).
Conclusions:
This study found that infrared non-touch forehead thermometry consistently produced higher temperature readings in adults compared with other common forms of peripheral thermometry. Caution should be taken when using forehead non-touch thermometer readings interchangeably with digital oral and digital axillary readings unless corrections for bias are made. More research is needed into whether infrared non-touch forehead thermometry and infrared tympanic could be used interchangeably.
Impact Statement:
This study aimed to address whether non-touch forehead could be used interchangeably with other common forms of non-invasive thermometry. Our result revealed inconsistencies in temperature readings between the different thermometers. Consequently, healthcare professionals should exercise caution when monitoring temperature trends where readings have been taken by different types of peripheral thermometers. This study could impact healthcare clinicians responsible for the monitoring and recording of peripheral temperatures.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...