Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Pressure pulsations enhance penetration index in COPD
Noam Gavriely1,2,3, Olga Volkov4, Gershon Fink5
1Department of Physiology, IIT Haifa, 33095, Technion, Israel. noam@karmelmedical.com.
Abstract:
This study was done in order to evaluate the effect of a novel pressure pulsation device (Pulsehaler™, Respinova Ltd., Israel) on the deposition pattern of inhaled aerosol in the lungs of COPD patients. Fifteen COPD patients were recruited to undergo spirometry and SPECT-CT lung scan following nebulization of radioactively labeled albuterol in saline solution with a jet nebulizer ("NEB") and with a combined Pulsehaler™/jet nebulizer ("PH + NEB") treatment. Central and peripheral segments of the coronal and transverse SPECT scans were evaluated for total counts and for the ratios between peripheral counts and central counts (penetration Index, "PI"). There was a significant improvement in FEV1 from before to after albuterol treatment in the PH + NEB group (151 ml ± 187, p < 0.008), but not in the NEB only group (66 ml ± 125, p = 0.06). FVC, FEF25-75, FEV1%, FVC%, FEF25, FEF50, and FEF75 also improved significantly in the PH + NEB group but not the NEB group. There were significant improvements seen between treatments for FEF25-75 (PH + NEB > NEB, p = 0.0176), FEF75 (PH + NEB > NEB, p = 0.0028), but not for the other spirometry measures. Borg scores also were improved significantly improved in PH + NEB vs NEB (p = 0.0006). Total lung deposition and total body deposition were lower in the PH + NEB treatments vs the NEB treatments. However, PI values were 3.08 ± 0.67 times greater on average with the PH + NEB (p = 0.026) as compared to NEB only. The magnitude of the increased penetration index observed in this study indicates that pressure pulsations should be further explored as means to improve drug delivery into the distal small airways of the bronchial tree. Effects of the pressure pulsations on small airway patency could be the mechanism by which the effect was achieved.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-III: Symptoms and Complications.
Symptoms of COPD can be classified as primary or systemic. Primary symptoms relate to reduced airflow, while systemic or extrapulmonary symptoms relate to COPD's broader impact on the body.
Primary Symptoms of COPD:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...