An immunochromatographic sensor for ultrasensitive and direct detection of histamine in fish
Lu Zeng1, Xinxin Xu1, Lingling Guo1
1State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China.
Abstract:
To ensure food quality and prevent histamine (HA) toxicity, a rapid and direct method of detecting HA is required. In this work, we prepared a monoclonal antibody (mAb) against HA using a hapten produced by the introduction of a phenyl-containing linker. The novel mAb exhibited high sensitivity against HA as determined by ELISA, with a half-maximal inhibitory concentration of 21.51 ng/mL. A gold nanoparticle-based immunosensor was fabricated for rapid detection of HA in fish samples. After optimizing the immunosensor, a visual limit of detection (LOD) and a calculated LOD were 0.25 mg/kg and 10.48 μg/kg for HA, respectively. Recovery rates from the spiked fish samples ranged from 87.33% to 104.67% with the coefficient of variation below 10.82%. Concurrently, the whole process in testing real sample was completed within 15 min, and all results were well confirmed and comparable by liquid chromatography-mass spectrometry and the commercial test strip. These data revealed that the proposed immunosensor could be used as a monitoring tool for the rapid and direct detection of HA in fish samples.