Cold-Injection Molded Gentamicin-Impregnated Polymethyl Methacrylate Implants for Cranioplasty
Related Experiment Video
Updated: Oct 26, 2025

Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Mena Mekhael Fahem1, Nabeel Hameed Ali1, Joseph Ravindra Duddu1
1Department of Clinical Neuroscience, Salmaniya Medical Complex, Ministry of Health, Manama, Kingdom of Bahrain.
Background:
Cranioplasty can be carried out using either fresh, frozen autologous bone or synthetic substitutes. Ordering artificial 3 dimensional (3D) implants is challenging and time consuming depending on geographical location. In this article, we share our experience using a streamlined process of producing 3D computer-assisted design (CAD) implants using commercially available 3D printers and silicone molds that can be easily replicated with consistent results and are associated with good outcomes.
Objective:
To develop patient-specific implants for patients with cranial defects that are accurate, consistent, low cost, and easy to replicate while reducing operator-dependent factors.
Methods:
We present data from 15 patients who underwent cranioplasty with 3D CAD-designed gentamicin-impregnated bone cement implants that were molded using the cold injection technique.
Results:
The technique was consistent in result production, required little postdemolding manipulation, and showed no dimensional variation in design. Postoperative computed tomography scans showed excellent implant fit, and patients had a low complication rate.
Conclusion:
We have demonstrated a technique of mold preparation that is efficient and that produces a reliable result. Polymethyl methacrylate implants molded using this technique showed better reproducibility, higher accuracy, and precision than other types of implants and required minimal postdemolding clean-up.