Background:
The colonoscopy withdrawal time (WT) and adenoma detection rate (ADR) are widely used quality indicators for colonoscopy. However, no study has investigated the appropriate colonoscopy WTs of individual colonic segments that will allow trainees to achieve a higher ADR. Thus, we analyzed for the first time the relationship between colonoscopy WT and the ADR/polyp detection rate (PDR) in the proximal, left-sided and entire colon among trainees.
Methods:
This retrospective study involved 611 consecutive patients who underwent colonoscopy from March 2018 to March 2019 performed by 6 trainees in the Endoscopy Center of Shanghai General Hospital. The WTs for the individual colonic segments and any significant findings of colonoscopies were retrospectively retrieved from the trainees' records and verified in the endoscopy center database. ADR/PDR was defined as the number of colonoscopies detecting at least 1 polyp/adenoma divided by the total number of colonoscopies. Comparisons of PDR and ADR between the 2 groups were conducted using chi-square test. Multilevel analysis was performed to consider individual differences among the 6 trainees. Multilevel binary logistic regression analysis was performed to analyze the factors that influenced the PDR, ADR and advanced adenoma detection rate (AADR) for the entire colon, and trainee status was included as a random effect.
Results:
The mean WTs were 4.20±1.09, 4.27±1.12, and 8.48±1.87 minutes for the proximal, left-sided, and entire colon, respectively. A longer WT [odds ratio (OR) 1.499, 95% confidence interval (CI): 1.381-1.628, P<0.001; OR 1.409, 95% CI: 1.265-1.569, P<0.001, respectively] was significantly associated with a higher PDR and ADR. The PDR (P<0.001) and ADR (P<0.001) were significantly higher when the WT was >4 minutes than when the WT was ≤4 minutes in both the proximal and left-sided colon, while the PDR (P<0.001) and ADR (P<0.001) were significantly higher when the WT was >8 minutes in the entire colon.
Conclusions:
In order to improve trainee colonoscopy performance, trainees were recommended to have WTs of at least 4 minutes in the proximal colon, 4 minutes in the left-sided colon and 8 minutes in the entire colon during negative screening colonoscopies.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Endoscopic Procedures III: Video Capsule Endoscopy
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...