Factors affecting compliance with positive airway pressure therapy in obstructive sleep apnea
Merve Ercelik1, Ege Gulec Balbay2, Pınar Yıldız Gulhan2
1Department of Chest Diseases, Afyonkarahisar Dinar State Hospital, 03400, Dinar, Afyonkarahisar, Turkey. merveercelik8@gmail.com.
Objective:
To investigate the factors affecting compliance with positive airway pressure (PAP) therapy and establish the relationship between compliance and pulmonary function tests (PFT) in patients with OSA.
Material And Methods:
In this prospective study, patients with OSA using PAP devices were questioned about the complaints related to the device. Depression and anxiety scales along with PFT parameters were also assessed.
Results:
Of 98 participants, 63% were men. The mean age was 52.0 ± 9.6 years. Sixty-seven percent of the patients were compliant with their devices. A significant difference was observed between the proportion of the participants compliant or non-compliant with the device, based on OSA severity (p < 0.05). Beck depression inventory (BDI) and Beck anxiety inventory (BAI) scores of the compliant patients were significantly lower than those of the non-compliant patients (p < 0.001, p = 0.044, respectively). No statistically significant difference was detected between the groups regarding individual pulmonary function tests (p > 0.05). The rates of nasal mask use, not having difficulty in tolerating CPAP, falling asleep, absence of abdominal distension, no facial sores, no air leakage, patients benefiting from the device, reduction in daytime sleepiness, and the belief that they are receiving appropriate therapy in participants compliant with the device were higher than those in non-compliant participants (p < 0.05). The rates of claustrophobia and discomfort due to pressure were significantly lower in patients compliant with the device than in the non-compliant patients (p < 0.05).
Conclusion:
While no relationship was detected between PFT parameters and PAP therapy compliance, significant factors affecting the device compliance were detected.
More Related Videos
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Cardiopulmonary Resuscitation II: ACLS Airway Management