Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

964
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
964
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

634
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
634
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

11.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.2K
The Quantum-Mechanical Model of an Atom02:45

The Quantum-Mechanical Model of an Atom

53.8K
Shortly after de Broglie published his ideas that the electron in a hydrogen atom could be better thought of as being a circular standing wave instead of a particle moving in quantized circular orbits, Erwin Schrödinger extended de Broglie’s work by deriving what is now known as the Schrödinger equation. When Schrödinger applied his equation to hydrogen-like atoms, he was able to reproduce Bohr’s expression for the energy and, thus, the Rydberg formula governing hydrogen spectra.
53.8K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

7.9K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
7.9K
2D NMR: Overview of Heteronuclear Correlation Techniques01:18

2D NMR: Overview of Heteronuclear Correlation Techniques

391
Heteronuclear correlation spectroscopy is an analytical technique that investigates the coupling between different types of nuclei, often a proton and an X-nucleus, such as carbon-13 or nitrogen-15. This method is commonly used in nuclear magnetic resonance (NMR) spectroscopy to gain insights into complex chemical compounds' structural and compositional aspects. A typical heteronuclear correlation spectrum displays X-nucleus chemical shifts on one axis and a proton spectrum on the other...
391

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Characterizing a high-dimensional unitary transformation without measuring the qudit it transforms.

Optics letters·2026
Same author

Noise-resistant phase imaging with intensity correlation.

Science advances·2023
Same author

One-Photon Measurement of Two-Photon Entanglement.

Physical review letters·2023
Same author

Resolution limit in quantum imaging with undetected photons using position correlations.

Optics express·2021
Same author

Causal Modeling the Delayed-Choice Experiment.

Physical review letters·2018
Same author

Erratum: Entanglement by Path Identity [Phys. Rev. Lett. 118, 080401 (2017)].

Physical review letters·2017
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Oct 26, 2025

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
07:56

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

Published on: September 5, 2019

8.7K

Position correlation enabled quantum imaging with undetected photons.

Balakrishnan Viswanathan, Gabriela Barreto Lemos, Mayukh Lahiri

    Optics Letters
    |July 30, 2021
    PubMed
    Summary
    This summary is machine-generated.

    Quantum imaging with undetected photons (QIUP) uses correlated photon pairs. This study explores QIUP using position correlation, differing from current momentum-based methods, revealing distinct image properties.

    More Related Videos

    Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
    12:19

    Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

    Published on: April 4, 2017

    8.6K
    Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
    09:23

    Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators

    Published on: May 30, 2014

    14.8K

    Related Experiment Videos

    Last Updated: Oct 26, 2025

    A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
    07:56

    A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference

    Published on: September 5, 2019

    8.7K
    Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source
    12:19

    Measurement of Quantum Interference in a Silicon Ring Resonator Photon Source

    Published on: April 4, 2017

    8.6K
    Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
    09:23

    Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators

    Published on: May 30, 2014

    14.8K

    Area of Science:

    • Quantum optics
    • Quantum imaging technologies

    Background:

    • Quantum imaging with undetected photons (QIUP) is an advanced imaging technique.
    • QIUP circumvents the need to detect photons that illuminate the target.
    • Existing QIUP methods rely on the momentum correlation of entangled photon pairs.

    Purpose of the Study:

    • To investigate an alternative QIUP approach utilizing position correlation between photon pairs.
    • To develop a general theoretical framework for position-correlated QIUP.
    • To compare the imaging properties of momentum-correlated versus position-correlated QIUP.

    Main Methods:

    • Theoretical analysis of quantum imaging principles.
    • Formulation of a quantum imaging model based on position-correlated photons.
    • Comparative study of image characteristics derived from momentum and position correlations.

    Main Results:

    • A general theory for QIUP based on position correlation is presented.
    • The study demonstrates that position-correlated QIUP yields distinct imaging properties compared to momentum-correlated QIUP.
    • Theoretical framework highlights unique characteristics of images formed via position correlation.

    Conclusions:

    • Position correlation offers a complementary pathway for quantum imaging with undetected photons.
    • The distinct properties of images generated by position-correlated QIUP open new possibilities in quantum imaging.
    • This research expands the theoretical understanding and practical potential of QIUP techniques.