Related Experiment Video
Updated: Oct 26, 2025

A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Hybrid model of photon propagation based on the analytical and Monte Carlo methods for a dual-head PET system
Fanzhen Meng1, Yu Shi1, Chenfeng Li1
1Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710071, People's Republic of China.
Abstract:
The construction of photon propagation has a close relationship with the quality of reconstructed images. The classical Monte Carlo (MC) based method can model the photon propagation precisely, but it is time-consuming. The analytical method can often quickly construct a model, but its precision is a problem. How to fully exploit the advantages of the MC simulation and analytical model is an open problem. Inspired by the characteristics of the depth of interaction (DOI) detectors, which can help confirm the deposited position of a photon with DOI-encoding technology, we virtually discretize each crystal into several subcrystals to obtain the statistical distribution by MC-based simulation. Then, the statistical distribution is combined with a spatially variant solid-angle model. This combination strategy provides a hybrid model to describe photon propagation with relatively high accuracy and low computational cost. Three discretization schemes are compared to optimize the constructed photon propagation model. Several experiments are carried out to evaluate the performance of the proposed hybrid method. The metrics of full width at half maximum (FWHM), contrast recovery (CR), and coefficient of variation (COV) are adopted to quantitate the imaging results. The classical MC-based method is compared as a gold-standard reference. When a crystal is divided into two discretized positions, the convergent tendencies of CRs and COVs are consistent with that based on MC simulation method, respectively. In terms of FWHMs, the resolutions of using the MC-based model and the proposed hybrid model are 0.71 mm and 0.68 mm in the direction parallel to the detector head, respectively. This indicates the potential of the proposed method in positron emission tomography imaging.
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by

