Related Experiment Video
Updated: Oct 26, 2025

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Comparing JM-105 and MBJ-20 Transcutaneous Bilirubinometers According to the Area Tested in Ethnically Diverse
Marjan Khajehei1, Seng Chai Chua, Beata Gidaszewski
1Department of Women's & Newborn Health, Westmead Hospital, Westmead, New South Wales, Australia (Dr Khajehei, Dr Chua, and Mss Gidaszewski and Swain); Westmead Clinical School, The University of Sydney, Sydney, New South Wales, Australia (Dr Khajehei and Ms Gidaszewski); University of New South Wales, Sydney, New South Wales, Australia (Dr Khajehei); and Western Sydney University, Sydney, New South Wales, Australia (Dr Chua).
Abstract:
This study aims to evaluate the correlation between the results of transcutaneous bilirubin (TcB) levels measured by the 2 transcutaneous bilirubinometers according to the area tested and to compare the TcB measurements and the serum bilirubin (SBR) levels. We screened 78 neonates born at more than 35 weeks of gestation and aged less than 168 hours for jaundice. We used JM-105 and MBJ-20 to measure the TcB at the forehead and the chest. For newborns who had high TcB measurements, we obtained blood samples during the subsequent 30 minutes. There was a strong correlation between the TcB measurements by JM-105 and MBJ-20 and this correlation was stronger when they were used on the sternum. The mean differences between the TcB measurements on the forehead and the sternum and the SBR levels were similar for the JM-105 and the MBJ-20. There was a strong correlation between SBR and the measurements using the 2 devices on the sternum (JM-105: r = 0.805; MBJ-20: r = 0.801), unlike measurements taken on the forehead by each device (r = 0.777 and r = 0.751, respectively). Both devices had high sensitivity and negative predictive values at SBR level of less than 230 μmol/L (<13.4 mg/dL) and high specificity and positive predictive values at SBR level of 230 μmol/L and greater (>13.4mg/dL). Both devices equally overestimated the actual SBR and had more reliable results if used on the sternum.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Measurement of Bioavailability: Pharmacodynamic Methods

