Related Experiment Video
Updated: Oct 26, 2025

Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
Published on: May 23, 2025
Comparison of Conventional Methods for Bowel Length Measurement in Laparoscopic Surgery to a Novel Computer-Assisted
Martin Wagner1, Benjamin F B Mayer1, Sebastian Bodenstedt2
1Department of General, Visceral and Transplantation Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
Purpose:
Accurate laparoscopic bowel length measurement (LBLM), which is used primarily in metabolic surgery, remains a challenge. This study aims to three conventional methods for LBLM, namely using visual judgment (VJ), instrument markings (IM), or premeasured tape (PT) to a novel computer-assisted 3D measurement system (BMS).
Materials And Methods:
LBLM methods were compared using a 3D laparoscope on bowel phantoms regarding accuracy (relative error in percent, %), time in seconds (s), and number of bowel grasps. Seventy centimeters were measured seven times. As a control, the first, third, fifth, and seventh measurements were performed with VJ. The interventions IM, PT, and BMS were performed following a randomized order as the second, fourth, and sixth measurements.
Results:
In total, 63 people participated. BMS showed better accuracy (2.1±3.7%) compared to VJ (8.7±13.7%, p=0.001), PT (4.3±6.8%, p=0.002), and IM (11±15.3%, p<0.001). Participants performed LBLM in a similar amount of time with BMS (175.7±59.7s) and PT (166.5±63.6s, p=0.35), but VJ (64.0±24.0s, p<0.001) and IM (144.9±55.4s, p=0.002) were faster. Number of bowel grasps as a measure for the risk of bowel lesions was similar for BMS (15.8±3.0) and PT (15.9±4.6, p=0.861), whereas VJ required less (14.1±3.4, p=0.004) and IM required more than BMS (22.2±6.9, p<0.001).
Conclusions:
PT had higher accuracy than VJ and IM, and lower number of bowel grasps than IM. BMS shows great potential for more reliable LBLM. Until BMS is available in clinical routine, PT should be preferred for LBLM.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...