Related Experiment Video
Updated: Oct 26, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Experimental investigation of efficient and simple wind-turbine based on DFIG-direct power control using LCL-filter
Fayssal Amrane1, Bruno Francois2, Azeddine Chaiba3
1Research Automatics Laboratory of Setif (LAS), Department of Electrical Engineering, Ferhat ABBAS University of Setif-1, Setif, Algeria; Laboratoire d'Electrotechnique et d'Electronique de Puissance de Lille (L2EP), Ecole Centrale de Lille, Lille, France.
Abstract:
This paper suggests an experimental implementation study of the Wind Energy Conversion System (WECS) based on efficient Direct Power Control (DPC). Stand-alone mode for variable wind speed application using Doubly-Fed Induction Generator (DFIG) is studied and developed in this work. Due to the wind power performance limitation of traditional PI controllers, such as overshoot, response time, and static error; IP (integral-Proportional) controllers is replaced instead of the PI to control rotor current d-q components (Ird and Irq) in a Park frame through AC-DC-AC converter. A comparative experimental study was implemented to improve the power quality using L, LC & LCL passive filters between the DFIG's rotor circuit and the inverter. Experimental results prove that the proposed DPC under stand-alone mode with LCL-Type filter could operate in several conditions despite the sudden wind speed variations. It improves the unity power factor grid operation (≈0.98), dynamic responses, and the decoupled power control with high wind power performances: good reference tracking, short response time, neglected overshoot, and low power error. The power quality injected into the RL-load satisfied the limit specified by IEEE harmonic standard 519 (less than 5%).
More Related Videos
08:35Interactive and Visualized Online Experimentation System for Engineering Education and Research
Published on: November 24, 2021
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Turbine-Governor Control
Generator Voltage Control
Load-frequency control
Control of Power Flow
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...