Dynamic spatial dispersion of repolarization is present in regions critical for ischemic ventricular tachycardia
Neil T Srinivasan1,2,3,4, Jason Garcia2, Richard J Schilling2
1Department of Cardiac Electrophysiology, The Essex Cardiothoracic Centre, Basildon, Essex, United Kingdom.
Background:
The presence of dynamic substrate changes may facilitate functional block and reentry in ventricular tachycardia (VT).
Objective:
We aimed to study dynamic ventricular repolarization changes in critical regions of the VT circuit during sensed single extrastimulus pacing known as the Sense Protocol (SP).
Methods:
Twenty patients (aged 67 ± 9 years, 17 male) underwent VT ablation. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular SP pacing at 20 ms above ventricular effective refractory period. Ventricular repolarization maps were constructed. Ventricular repolarization time (RT) was calculated from unipolar electrogram T waves, using the Wyatt method, as the dV/dtmax of the unipolar T wave. Entrainment or pace mapping confirmed critical sites for ablation.
Results:
The median global repolarization range (max-min RT per patient) was 166 ms (interquartile range [IQR] 143-181 ms) during SR mapping vs 208 ms (IQR 182-234) during SP mapping (P = .0003 vs intrinsic rhythm). Regions of late potentials (LP) had a longer RT during SP mapping compared to regions without LP (mean 394 ± 40 ms vs 342 ± 25 ms, P < .001). In paired regions of normal myocardium there was no significant spatial dispersion of repolarization (SDR)/10 mm2 during SP mapping vs SR mapping (SDR 11 ± 6 ms vs 10 ± 6 ms, P = .54). SDR/10 mm2 was greater in critical areas of the VT circuit during SP mapping 63 ± 29 ms vs SR mapping 16 ± 9 ms (P < .001).
Conclusion:
Ventricular repolarization is prolonged in regions of LP and increases dynamically, resulting in dynamic SDR in critical areas of the VT circuit. These dynamic substrate changes may be an important factor that facilitates VT circuits.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias