Related Experiment Video
Updated: Oct 26, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Incidence of acquired ventricular septal defect after transcatheter aortic valve replacement: A large single center
Paul Nona1, Shazil Mahmood1, Alejandro Lemor1
1Division of Cardiology, Henry Ford Health System, Detroit, Michigan, USA.
Objective:
To determine the rate and clinical outcomes of post-TAVR VSD.
Background:
Transcatheter aortic valve replacement (TAVR) is a safe and established procedure for patients with severe symptomatic aortic stenosis. Ventricular septal defect (VSD) is a rare complication of TAVR. The rate of post-TAVR VSD and patient outcomes are not well known.
Methods:
A retrospective record review of VSD cases occurring after all TAVRs performed between January 2012 and September 2020 at one urban US tertiary hospital. VSD rate and early- and long-term outcomes were analyzed. Computed tomography images taken before TAVR and transthoracic echocardiograms done before and after each procedure were analyzed.
Results:
Of the 1908 patients who underwent TAVR in the study period, 7 patients (0.37%) had post-procedure VSD. The average patient age was 77 ± 11 years with average society of thoracic surgeons short-term risk score of 6%. All 7 implanted valves were balloon-expandable. Of the 7 TAVR procedures, 5 were performed on a native tricuspid valve, 1 was performed on a native bicuspid valve, and 1 was done as a "valve-in-valve" procedure on a prior surgical bioprosthetic valve. All VSDs were small and restrictive in nature. Right heart failure in a patient with preexisting right ventricular dysfunction occurred in 1 (13%) patient who died. The remaining 6 patients (86%) were discharged. All 6 patients (86%) were alive and stable at 1 year follow-up, reporting improvement in symptoms (NYHA class I-II), with no evidence of right ventricular dysfunction.
Conclusion:
VSD is a rare complication of TAVR. Hemodynamic and clinical sequelae in majority of the patients in this study did not result in mortality. Proper imaging techniques and appropriate pre-procedure planning are needed to decrease the incidence of VSD formation post-TAVR.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests