Related Experiment Video
Updated: Oct 25, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Does Contrast Dose Based in Lean body Weight Allow Lesser Volumes on High BMI Patients for CT Angiography?
Rajsekar Chandrasekharan1, Chinmay Bhimaji Kulkarni1, Sreekumar Karumathil Pullara1
1Department of Radiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India.
Objectives:
The objective was to evaluate whether contrast dose based on lean body weight (LBW) protocol has the potential to reduce contrast volume in patients with high basal metabolic index (BMI) compared to total body weight (TBW)-based protocols.
Material And Methods:
The Institutional Review Board approval was obtained for this prospective study. Initially, a pilot study with a sample size of 150 patients was conducted to estimate the average fat fraction in our population. Then, CT angiography (CTA) for the thoracic and abdominal aorta was performed using a 256-multidetector computed tomography scanner in 117 patients who were undergoing screening for aortic aneurysm and vascular assessment of prospective transplant donors. The patients were divided into two groups: A TBW group (n = 60) and LBW group (n = 57). Lean body weight (LBW) was estimated from the patient weight, height, and gender using Hume's equation. The TBW group received 1.2 ml/kg contrast dose and the LBW group received 1.6 ml/kg contrast dose to achieve approximately equal iodine dose in both groups. Differences in the degree of aortic enhancement between the estimated LBW and TBW group were evaluated. In higher BMI patients (>25), the mean aortic enhancement (MAEnh) and the contrast volume delivered between the LBW and TBW group were compared.
Results:
Mean aortic enhancement (MAEnh) 422.45 (±74.5) Hounsfield unit (HU) in the TBW group and 432.67 (±69.4) HU in the LBW group showed no statistical difference (P = 0.439). In population with BMI >25, the contrast delivered in LBW protocol patients was significantly less (P = 0.00) compared to TBW protocol patients, with no significant difference in the MAEnh between the groups (P = 0.479).
Conclusion:
CTA using a LBW protocol helps to significantly reduce the volume of contrast delivered, especially in patients with BMI >25 compared to TBW protocol, without compromising the aortic enhancement.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Drug Dosing: Obese Patients
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...