Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic
Márcio Luís Duarte1, Lucas Ribeiro Dos Santos2, Acary Souza Bulle Oliveira3
1MD, MSc. Musculoskeletal Radiologist, WEBIMAGEM, São Paulo (SP), Brazil; and Doctoral Student in Evidence-based Health Program, Universidade Federal de São Paulo (UNIFESP), São Paulo (SP), Brazil.
Background:
Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether CT with a low radiation dose has a fracture detection rate similar to that of standard-dose CT.
Objective:
To determine the detection rate of low-dose radiation CT and standard-dose radiation CT for fractures, in patients with suspected fractures.
Design And Setting:
Systematic review of comparative studies on diagnostic accuracy within the evidence-based health program at a federal university in São Paulo (SP), Brazil.
Methods:
We searched the electronic databases Cochrane Library, MEDLINE, EMBASE and LILACS up to June 29, 2020, for studies evaluating the detection rates of low-dose CT and standard-dose CT for diagnosing bone fractures. The Research Triangle Institute (RTI) item bank tool was used for methodological quality evaluation.
Results:
The fracture detection rate according to the number of bones evaluated, using CT with low-dose radiation was 20.3%, while with standard-dose radiation it was 19.2%, and the difference between the methods was not significant. The fracture detection rate according to the number of patients, using CT with low-dose radiation was 56.0%, while with standard-dose radiation it was 58.7%, and this difference between the methods was not significant, either.
Conclusion:
CT with low-dose radiation presented detection rates similar to those of CT with standard-dose radiation, regardless of the bones evaluated.
Registration Number:
CRD42019148491 at the PROSPERO database.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT