Related Experiment Video
Updated: Oct 25, 2025

Author Spotlight: Advancing Pathogen Detection and Disease Assessment in Real-Time Using M-ROSE
Published on: March 1, 2024
Rapid On-Site Evaluation by Endosonographer of Endoscopic Ultrasound Fine-Needle Aspiration of Solid Pancreatic
João Autran Nebel1, Monica Soldan1, Jean-Marc Dumonceau2
1From the Gastroenterology Service, Hospital Universitário Clementino Fraga Filho, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
Objectives:
Rapid on-site evaluation (ROSE) by cytopathologists during endoscopic ultrasound-fine-needle aspiration (EUS-FNA) of solid pancreatic lesions (SPLs) improves adequacy and diagnostic accuracy while reducing the number of needle passes. We evaluated the usefulness of ROSE performed by the endosonographer.
Methods:
Patients with an SPL were randomly assigned to EUS-FNA with ROSE or non-ROSE. Procedure duration, number of needle passes, specimen adequacy, and adverse event rates were compared.
Results:
Sixty-five patients were enrolled (33 in the ROSE vs 32 in the non-ROSE group). Both groups were similar in terms of age, sex, size, and location of the lesion. Specimen adequacy rates were high and similar between groups. Mean (standard deviation) procedure duration was shorter in the ROSE versus non-ROSE group (30.0 [11.3] vs 37.0 [7.2] minutes, P < 0.005), as well as the mean (standard deviation) number of needle passes (2.6 [0.8] vs 3.5 [0.8], P < 0.005). Accuracy parameters as sensitivity and accuracy of ROSE by the endosonographer for malignancy were 93% and 88%, respectively.
Conclusions:
After specific training, the endosonographer can accurately evaluate samples during EUS-FNA of SPL, allowing for a shorter procedure duration and a lower number of needle passes.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures V: ERCP
Patient...