Estimation of occupational radiation doses in neuroendovascular procedures
D López-Ángeles1, I Gamboa-deBuen2, C Martínez-de Los Santos3
1Facultad de Ciencias, Universidad Nacional Autónoma de México, A.P. 70-543, 04510 CDMX, Mexico.
Abstract:
To estimate the mean effective dose per procedure with multiple dosimetry, to calculate the annual effective dose to personnel working in neuroendovascular procedures and compared with methods reported in the literature and with national and international limits. The radiation dose to personnel was monitored in 20 procedures classified as diagnostic or therapeutic. During each procedure, the equivalent dose to eyes, thyroid, under and over the lead apron at chest level, hands, gonads and knees was measured with lithium fluoride thermoluminescent dosimeter chips (TLD-100). Estimations of the annual effective dose from different methods found in literature that use one or two dosimeters and from this work were compared. Also, a comparison was made with the safety limits recommended in national and international regulations. Radiation exposure to eyes, thyroid, gonads and knees is relevant to the effective dose, and therefore to the annual effective dose estimations. Personnel position is important, as the performing physician, who is closer to the patient, received the highest dose measured. In particular, this was observed in the equivalent dose received over the apron. However, the equivalent dose to the right eye was higher for neuroanaesthesiologists than for performing physicians due to their position relative to the patient. In general, effective doses estimated using one- and two-dosimeter methods found in the literature were, respectively, lower and higher than those obtained with the ten-dosimeter method in this work. The annual effective doses to personnel estimated with the multiple dosimetry algorithm ranged from 1.3 to 1.5 mSv y-1and are within the national and international limits.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Aneurysm IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...