MRI software for diffusion-perfusion mismatch analysis may impact on patients' selection and clinical outcome
Silvia Pistocchi1, Davide Strambo2, Bruno Bartolini1
1Diagnostic Neuroradiological Unit, Service of Diagnostic and Interventional Radiology, Department of Medical Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Objective:
Impact of different MR perfusion software on selection and outcome of patients with acute ischemic stroke (AIS) and large vessel occlusion (LVO) treated by endovascular thrombectomy (EVT) is unclear. We aimed at comparing two commercial MRI software, semi-automated with unadjusted (method A) and adjusted mask (method B), and fully automated (method C) in this setting.
Methods:
MRI from 144 consecutive AIS patients with anterior circulation LVO was retrospectively analysed. All diffusion- and perfusion-weighted images (DWI-PWI) were post-processed with the three methods using standard thresholds. Concordance for core and hypoperfusion volumes was assessed with Lin's test. Clinical outcome was compared between groups in patients who underwent successful EVT in the early and late time window.
Results:
Mean core volume was higher and mean hypoperfusion volume was lower in method C than in methods A and B. In the early time window, methods A and B found fewer patients with a mismatch ratio ≤ 1.2 than method C (1/67 [1.5%] vs. 12/67 [17.9%], p = 0.0013). In the late time window, methods A and B found fewer patients with a mismatch ratio < 1.8 than method C (3/46 [6.5%] and 2/46 [4.3%] vs. 18/46 [39.1%], p ≤ 0.0002). More patients with functional independence at 3 months would not have been treated using method C versus methods A and B in the early (p = 0.0063) and late (p ≤ 0.011) time window.
Conclusions:
MRI software for DWI-PWI analysis may influence patients' selection before EVT and clinical outcome.
Key Points:
• Method C detects fewer patients with favourable mismatch profile. • Method C might underselect more patients with functional independence at 3 months. • Software used before thrombectomy may influence patients' outcome.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...