Hemodynamic Responses in Lower Limb Lymphedema Patients Undergoing Physical Therapy
Bianca Brix1, Olivier White2, Christian Ure3
1Gravitational Physiology and Medicine Research Unit, Division of Physiology, Otto Loewi Research Center, Medical University of Graz, 8010 Graz, Austria.
Background:
Lymphedema arises due to a malfunction of the lymphatic system, leading to extensive tissue swelling. Complete decongestive therapy (CDT), which is a physical therapy lasting for 3 weeks and includes manual lymphatic drainages (MLD), leads to fluid mobilization and increases in plasma volume. Here, we investigated hemodynamic responses induced by these fluid shifts due to CDT and MLD.
Methods:
Hemodynamic parameters were assessed continuously during a sit-to-stand test (5 min baseline, 5 min of standing, and 5 min of recovery). This intervention was repeated on days 1, 2, 7, 14, and 21 of CDT, before and after MLD. Volume regulatory hormones were assessed in plasma samples.
Results:
A total number of 13 patients took part in this investigation. Resting diastolic blood pressure significantly decreased over three weeks of CDT (p = 0.048). No changes in baseline values were shown due to MLD. However, MLD led to a significant decrease in heart rate during orthostatic loading over all epochs on therapy day 14, as well as day 21. Volume regulatory hormones did not show changes over lymphedema therapy.
Conclusion:
We did not observe any signs of orthostatic hypotension at rest, as well as during to CDT, indicating that lymphedema patients do not display an elevated risk of orthostatic intolerance. Although baseline hemodynamics were not affected, MLD has shown to have potential beneficial effects on hemodynamic responses to a sit-to-stand test in patients undergoing lymphedema therapy.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Artery Disease IV: Nursing Management
Venous Thrombosis IV: Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease III: Interprofessional Care