Microstructural Study of Arc Beads in Aluminum Alloy Wires with an Overcurrent Fault

Xueyan Xu1,2, Zhijin Yu2, Yang Li2,3

  • 1Department of Justice Technology, Jilin Justice Officer Academy, Changchun 130062, China.

Related Concept Videos

Magnetic Force On Current-Carrying Wires: Example01:22

Magnetic Force On Current-Carrying Wires: Example

In a magnetic field, moving charges encounter a force. If a wire contains these moving charges, i.e., if the wire is carrying a current, then a force acts on the wire as well. Consider a pair of flexible leads holding a wire that is 40 cm long and 10 g in weight in a horizontal position. The wire is placed in a constant magnetic field of 0.40 T, as shown in Figure 1(a). Determine the magnitude and direction of the current flowing in the wire needed to remove the tension in the supporting leads.
1.7K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
3.4K
Thermal expansion and Thermal stress: Problem Solving01:27

Thermal expansion and Thermal stress: Problem Solving

San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
1.5K
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
286
Stress-Strain Diagram - Ductile Materials01:24

Stress-Strain Diagram - Ductile Materials

The stress-strain relationship in ductile materials such as structural steel or aluminium is intricate and progresses through several stages. When a specimen is loaded, it initially exhibits a linear length increase, depicted by a steep straight line on the stress-strain diagram. It indicates the material is elastically deforming and will return to its original shape once unloaded. However, when a critical stress value is reached, plastic deformation begins. This stage sees substantial...
1.1K
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
156