Moisture Distribution during Water Absorption of Ordinary Portland Cement Mortars Obtained with Low-Field Unilateral
Prisciliano Felipe de Jesús Cano-Barrita1, Floriberto Díaz-Díaz1
1Instituto Politécnico Nacional, CIIDIR Unidad Oaxaca, Calle Hornos No. 1003, Col. Noche Buena, Santa Cruz Xoxocotlán, Oaxaca 71230, Mexico.
Abstract:
Moisture distribution in cement-based materials is important from the durability point of view. In the present study, a portable three-magnet array with an elliptical surface radio frequency coil was used to undertake magnetic resonance measurements of moisture content in ordinary Portland cement mortar and concrete samples. Measurements along the length of the samples during capillary water absorption produced moisture content profiles that were compared with reference profiles acquired using a magnetic resonance imaging instrument. Profiles obtained with the three-magnet array were similar in shape and in penetration depth to those acquired with magnetic resonance imaging. The correlation coefficient between the moisture content measured with both techniques was r2 = 0.97. Similar values of saturated permeability of the mortars with identical w/c ratio were computed with the Hydrus 1D software based on the moisture content profiles. Additionally, inverse Laplace transformation of the signal decays provided the water-filled pore size distribution in saturated and unsaturated regions of the samples. The three-magnet array was successfully used to acquire nuclear magnetic resonance signal from a concrete sample, which was not possible with the magnetic resonance imaging instrument using the single-point imaging technique.
Related Concept Videos
Mortar Properties
Porosity in Cement Paste
The balance of water to cement in the mix is...
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
Mortar Joint Deterioration in Masonry
The...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...